NINGBO POPMODE amfori BSCI

Monitoring summary report for NINGBO POPMODE CLOTHING CO.,LTD.

MONITORING ID: 26-0393009 | Generated on 22/05/2026 | Source: amfori Sustainability Platform

1. MONITORING OVERVIEW

Monitored PartyNINGBO POPMODE CLOTHING CO.,LTD.
amfori ID156-005365-000
AddressMaimianqiao Village, Jishigang Town, Haishu District, 315171 Ningbo, Zhejiang Sheng, China
Monitoring Activityamfori Social Audit - Manufacturing
Monitoring TypeFull Monitoring
Monitoring PartnerALGI HOLDING COMPANY LLC
Monitoring Start Date13/05/2026
Closing Meeting Finished Date15/05/2026
Submission Date22/05/2026
Expiration Date22/05/2028
Announcement TypeSemi Announced
SiteNINGBO POPMODE CLOTHING CO.,LTD. (Site amfori ID: 156-005365-002)

Note: The OVERALL RATING in the source PDF is presented as a graphic and is not available in the extracted text. The SECTION RATING below is extracted from the text. Please refer to the original report for the complete rating.

SECTION RATING

Performance AreaRating
PA1: Social Management SystemC
PA 2: Workers Involvement and ProtectionB
PA 3: The Rights of Freedom of Association and Collective BargainingA
PA 4: No Discrimination, Violence or HarassmentA
PA 5: Fair RemunerationA
PA 6: Decent Working HoursC
PA 7: Occupational Health and SafetyA
PA 8: No Child LabourA
PA 9: Special Protection for Young WorkersA
PA 10: No Precarious EmploymentA
PA 11: No Bonded, Forced Labour or Human TraffickingA
PA 12: Protection of the EnvironmentA
PA 13: Ethical Business BehaviourA

2. GENERAL DESCRIPTION

Name of lead auditor:Irene Chen; APSCA membership number: CSCA 21701772.

Name of team auditor (if applicable):No team auditor; APSCA membership number: N/A.

Name of observers, translators, trainees, advisors/consultants (if applicable):N/A

Monitoring partner name:ALGI HOLDING COMPANY LLC; APSCA membership number: 11600033.

Audit schedule details:The Full audit (Semi - Announced) is planned for 1 auditor x 3.0 onsite days (Started on May 13, 2026) and finished audit on May 15, 2026.

Business partner information:NINGBO POPMODE CLOTHING CO.,LTD. (Local Name: 宁波宝珀制衣有限公司 Uniform Code of Social Credit: 91330212750350093M) was located at "Maimianqiao Village, Jishigang Town, Haishu District, Ningbo, Zhejiang Province, China (浙江省宁波市海曙区集士港镇卖面桥村)". The factory was established in May 2003 and specializes in the manufacturing of garments. Main production activities include cutting, sewing, ironing, inspection and packing. Printing process was subcontracted to "Ningbo Poyinte digital Technology Co., Ltd (宁波珀印特数码科技有限公司)" and embroidering process was subcontracted to "Ningbo Zhonghong Textile Co., Ltd (宁波中红纺织品有限公司)" if needed.

Audited location information:The audited factory used one 5-storey production building (about 12060 square meters), one flat production building (about 1280 square meters) and one 5-storey dormitory building (about 4565 square meters), and one flat electricity distribution room (about 150 square meters) and one boiler room (about 100 square meters) as office, dormitory, kitchen, canteen, warehouse and production workshops. The building details were as below: One 5-storey production building: 1/F: Used as cutting workshop. 2/F: Used as sewing and ironing workshops and warehouse. 3/F: Used as sewing workshop. 4/F: Used as ironing, inspection and packing workshops. 5/F: Used as office, finished goods warehouse and sample room. One flat production building was used as raw material warehouse. One 5-storey dormitory building: 1/F: Used as canteen and kitchen. 2/F~5/F: Used as dormitory rooms.

Operating shifts and hours:The kitchen workers worked for 1 shift: 8:00-13:00, 15:00-18:00; Other workers worked for 1 shift: 7:30-11:00,12:00-16:30. Normal working days are from Monday to Friday. Workers worked overtime voluntarily for 2 hours from 17:30 to 19:30 on normal working days and for 8 hours on Saturdays if need. The Sunday and holiday would be arranged to rest.

Time recording system:The factory used fingerprint electronic attendance system to record employees working hours.

Salary payment details:All employees in the factory were paid by monthly rate. Wages were paid monthly by bank transfer on the 15th of every month for the preceding month.

During the current audit, payroll records from April 2025 to March 2026 and attendance records from April 1, 2025 to May 15, 2026 were provided for review. The auditor randomly selected 22 samples from each of March 2026 (last paid month), December 2025 (random month) and August 2025 (random month) for verification.

Worker number information:On the day of audit, there were 427 employees present (89 non-production employees and 338 production workers). There were 338 production workers (108 male production workers and 230 female production workers) and 341 migrant workers (132 male workers and 209 female workers) were from other provinces in China. No any other special group workers (such as child labor, young, disabled, pregnant woman, interns, apprentices, contractor workers) were noted during this audit. As per management interview, no obvious peak or non-peak month in the past 12 months.

Good practices:NA

Worker organization details:No labor union was available. Four worker representatives were elected by workers.

Circumstances:Ms. Yao Yanping/HR Manager and Ms. Mo Yali / Worker Representative participated in the opening & closing meeting. The opening meeting started at 7:30 on May 13, 2026 and the closing meeting ended at 16:30 on May 15, 2026. The auditor communicated the findings in detail to them and allowed them to ask questions and make any needed clarifications. Finally, they agreed on the findings and signed the on-site audit findings report.

Special circumstances:The special circumstances can be classified as followed: No special circumstances were noted during this audit.

Summary of findings

  • PA1: Social Management System
    1.1 The social management system was not implemented effectively.
    1.4 Workforce capacity was not properly planned, which lead excessive overtime hours.
  • PA 2: Workers Involvement and Protection
    2.2 The factory did not establish the long-term goals.
  • PA 5: Fair Remuneration
    5.5 Insufficient participation of social insurances.
  • PA 6: Decent Working Hours
    6.2 Monthly overtime hours of one sample month exceeded 36 hours.
  • PA 7: Occupational Health and Safety
    7.1 Non-compliance with health and safety local law and regulations and goods were placed against the walls.
    7.7 Some chemicals were not set in secondary containers and were not identified with chemical safety labels.
    7.13 One electrical box was not locked or without inner covers.
    7.22 The factory did not provide some cleaning supplies in toilet.

Minimum wage calculation:The local legal minimum wage standard is CNY 2490 per month or equivalent to CNY 14.31 per hour before January, 2026 and CNY 2660 per month or equivalent to CNY 15.29 per hour since January 1, 2026. #Living Wage: [The audited factory was located in Ningbo City, the auditor used the Living wage calculation published on the GLWC website for the region (https://www.globallivingwage.org/living-wage-benchmarks/benchmark-report-2024-living-wage-report-for-ningbo-china/), which is estimated at the amount of CNY 4198 per month. As recommended, GLWC method of calculation is considered by the auditor for this audit. GLWC benchmark data are uploaded as part of the report attachments.]

Remark

  1. The government waiver, agency labor contract and collective bargaining agreement were not available for the factory on the audit day, which made those documents not applicable.
  2. Some uploaded attachments (such as wage records and time records) involve employees' personal information, which is protected. This is to comply with the requirements of the Personal Information Protection Law of the People's Republic of China and GDPR.
  3. The address on business license and amfori BSCI platform were "Maimianqiao Village, Jishigang Town, Haishu District, Ningbo, Zhejiang Province, China" and the current address was "No.78 Gongmao 1st Road, Maimianqiao Village, Jishigang Town, Haishu District, Ningbo, Zhejiang Province, China". Through onsite observation, documents review and management interview, both addresses were the same location and the current address was more detailed.

3. SITE DETAILS

SiteNINGBO POPMODE CLOTHING CO.,LTD.
Site amfori ID156-005365-002
GICS ClassificationSector: Consumer Discretionary; Industry Group: Consumer Durables & Apparel; Industry: Textiles, Apparel & Luxury Goods; Sub Industry: Apparel, Accessories & Luxury Goods
amfori Process ClassificationsSewing / Stitching
GS1 ClassificationsN.A.
NACE ClassificationN.A.
Water Stress SituationThis site is not located in a water stressed region

4. METRICS

Key Metrics

MetricValue
Total workforce427 Workers
Legal minimum wage in local currency2,660 Monthly
Lowest wage paid for regular work at the site4,750 Monthly
Calculated living wage in local currency4,198 Monthly
Total sample22 Workers
Show all Other Metrics (52 items)
MetricValue
Male workers156 Workers
Female workers271 Workers
Non-binary workers0 Workers
Permanent workers - Male156 Workers
Permanent workers - Female271 Workers
Permanent workers - Non-binary0 Workers
Temporary workers - Male0 Workers
Temporary workers - Female0 Workers
Temporary workers - Non-binary0 Workers
Seasonal workers - Male0 Workers
Seasonal workers - Female0 Workers
Seasonal workers - Non-binary0 Workers
Management - Male2 Workers
Management - Female3 Workers
Management - Non-binary0 Workers
Apprentices - Male0 Workers
Apprentices - Female0 Workers
Apprentices - Non-binary0 Workers
Workers on probation - Male0 Workers
Workers on probation - Female0 Workers
Workers on probation - Non-binary0 Workers
Workers with night shift - Male0 Workers
Workers with night shift - Female0 Workers
Workers with night shift - Non-binary0 Workers
Workers with disabilities - Male0 Workers
Workers with disabilities - Female0 Workers
Workers with disabilities - Non-binary0 Workers
Domestic migrant workers - Male132 Workers
Domestic migrant workers - Female209 Workers
Domestic migrant workers - Non-binary0 Workers
Foreign migrant workers - Male0 Workers
Foreign migrant workers - Female0 Workers
Foreign migrant workers - Non-binary0 Workers
Workers hired directly - Male156 Workers
Workers hired directly - Female271 Workers
Workers hired directly - Non-binary0 Workers
Workers hired indirectly - Male0 Workers
Workers hired indirectly - Female0 Workers
Workers hired indirectly - Non-binary0 Workers
Unionised workers - Male0 Workers
Unionised workers - Female0 Workers
Unionised workers - Non-binary0 Workers
Workers under CBA - Male0 Workers
Workers under CBA - Female0 Workers
Workers under CBA - Non-binary0 Workers
Pregnant workers0 Workers
Workers on parental leave - Male0 Workers
Workers on parental leave - Female0 Workers
Workers on parental leave - Non-binary0 Workers
Sample - Male8 Workers
Sample - Female14 Workers
Sample - Non-binary0 Workers

5. FINDINGS

Site: NINGBO POPMODE CLOTHING CO.,LTD. | Site amfori ID: 156-005365-002. The source report presented each finding in both English and the local language; this version reproduces the English text only.

PA1: Social Management System

Question 1.1

Is there satisfactory evidence that the auditee has set up an effective management system to implement the amfori BSCI Code of Conduct?

Based on documents review, onsite observation, management and worker interviews, it was noted that the factory did not have an effective management system regarding Social Management System, Workers Involvement and Protection, Fair Remuneration, Decent Working Hours, Occupational Health. (For details, please refer to Performance Area 1, 2, 5, 6 and 7 respectively.) The factory management claimed that they will make continuous improvement. This question is rated as partially due to the factory established the social responsibility procedures or management systems, but the non-conformances only noted in above PAs. This is partially in compliance with requirements of amfori BSCI CoC.

Question 1.4

Is there satisfactory evidence that the auditee's workforce capacity is properly organised to meet the expectations of the delivery order and/or contracts?

Based on documents review, onsite observation, management and worker interviews, it was noted that the factory developed the procedures about production capacity planning & cost accounting, the production capacity could satisfy the customer needs and all the goods could be delivered to the clients on time, but it was noted that the factory could not adequately evaluate the production capacity, human resources and equipment status against the delivery requirements to avoid the undue monthly overtime working, so that the workers' monthly overtime hours exceeded the law limit (For details, please refer to PA6.2). The factory management claimed that the factory had taken the action (e.g. optimizing production efficiency) to control the workers' overtime hours. The checkpoint was rated as partially because management staffs were clear of the production rate, date of delivery and regulatory working hours requirements, the factory made the detailed production plan for each order to arrange the production activities. This is partially in compliance with PRC Labor Law article 41.

PA 2: Workers Involvement and Protection

Question 2.2

Is there satisfactory evidence that the auditee defines long-term goals for protecting workers in line with the aspirations of the amfori BSCI Code of Conduct?

Based on documents review, management and worker interviews, the factory did not establish the long-term goals which met the requirements of the amfori BSCI Code of Conduct. The factory management claimed that they did not fully understand the difference between short-term investment and long-term goals before and would establish long-term goals to protect workers. This question is rated as no due to the factory did not establish the long-term goals. This is not in compliance with requirements of amfori BSCI CoC.

PA 5: Fair Remuneration

Question 5.5

Is there satisfactory evidence that the auditee provides workers with the social benefits that are legally granted without negative impact on their pay, level of seniority, position, or promotion prospects?

Based on management interview, workers interview and reviewing the social insurance participation from April 2025 to March 2026, it was noted that not all employees were provided with social insurance. In March 2026, there were total 427 employees (427 employees included 90 retired employees and 0 new employee), but only 300 out of 337 eligible employees (89.0%) were provided with pension, unemployment, medical and maternity insurances and 370 employees were provided with industrial injury insurances. The factory provided the group commercial injury insurance with the period from December 6, 2025 to December 5, 2026 to other 57 employees to make sure all employees were covered by injury insurance. No social insurance waiver was available. The factory management claimed that rest employees had new rural cooperative pension insurance and did not want to buy these 5 kinds of social insurances. This question is rated as partially due to the participation rate of the social insurances higher than 80% and all employees were covered by injury insurance. This is partially in compliance with the PRC Labor Law article 72 & 73.

PA 6: Decent Working Hours

Question 6.2 CRUCIAL

Is there satisfactory evidence that the auditee request of overtime is in line with the requirements of the amfori BSCI Code of Conduct?

Based on management interview, workers interview and documents review, it was noted that the monthly overtime working hours of 1 out of 3 randomly sampled months exceeded the legal limit of 36 hours per month. The details were as follow: the monthly overtime working hours of all 22 sampled workers were 32-34 hours in March 2026 (last paid month); The monthly overtime working hours of 21 workers out of 22 sampled workers were 40 hours in December 2025 (random month); The monthly overtime working hours of all 22 sampled workers were 32-34 hours in August 2025 (random month). The factory management claimed that urgent orders led to excessive monthly overtime working hours of this month. This question is rated as partially due to excessive monthly overtime working hours noted in just one sampled month. This is partially in compliance with the PRC Labor Law article 41. Remark: The workers' overtime work was voluntary.

PA 7: Occupational Health and Safety

Question 7.1

Is there satisfactory evidence that the auditee observes occupational health and safety regulations applicable for its activities?

Based on documents review, onsite observation, management and worker interviews, it was noted that: 1. the factory had set up its own occupational health and safety regulations and procedures, the actual practice throughout the factory was not fully in compliance with requirements of local laws in the part of Warehouse Safety, Chemical management and Electrical safety. The factory management claimed that they will make continuous improvement. This is partially in compliance with requirements of relevant local health and safety laws. (Please refer to question points PA7.1, PA7.7 & PA 7.13 for specific health and safety regulations.) 2. It was noted that around 20% goods in the warehouse were placed against the walls. The factory management claimed that limited space caused this happened. This is partially in compliance with the Rules Concerning Warehouse Safety and Fire Control article 18. This question is rated as partially due to the factory have awareness of occupational health and safety and assigned specialized management staff to take charge of it, but there are still the problems in the actual practice process of the factory.

Question 7.7

Is there satisfactory evidence that the auditee implements engineering and administrative control measures to avoid or minimise the release of hazardous substances into the work environment, keeping the level of exposure below internationally established or recognised limits?

Based on onsite observation, management and worker interviews, it was noted that about 10% chemicals used in the workshop such as clean agent were not set in secondary containers and were not identified with chemical safety labels. The factory management claimed that they did not inspect and review chemicals enough and failed to identify problems in a timely manner. This question is rated as partially due to most chemicals were set in secondary containers and were identified with chemical safety labels and provided the SDS onsite, but some chemicals were not set in secondary containers and were not identified with chemical safety labels. This is partially in compliance with Safety Management of Dangerous Chemicals Article 20 and Regulations on the Safe Use of Chemicals in Workplace, Article 12.

Question 7.13

Is there satisfactory evidence that the auditee makes sure a competent person periodically checks the electrical installations and equipment?

Based on documents review, onsite observation, management and worker interviews, 1 electrical box out of 10 sampled electrical boxes was not locked or without inner cover such as dormitory. The factory management claimed that the electrician did not check and lock in time. This question is rated as partially due to the factory had established the management program and protective covers were installed on most electrical boxes and switches and locked, but one electrical box was not locked or without inner cover. This is partially in compliance with the General Guide for Safety of Electric User (GB/T13869-2017), Article 5.1.2.

Question 7.22

Is there satisfactory evidence that the auditee provides workers with clean washing facilities, changing rooms and toilets that are also respectful of local customs?

Based on onsite observation, management and workers interview, it was noted that the factory did not provide some cleaning supplies such as toilet paper in toilet for employees use. The factory management claimed that they will buy the cleaning supplies soon. This question is rated as partially due to the sanitary condition was good in toilet in factory and the factory provided the soap in toilet, but the factory did not provide some cleaning supplies such as toilet paper in toilet for employees use. This is partially in compliance with requirements of amfori BSCI CoC.

Disclaimer

This is an extract of the online Monitoring Result, generated on 22/05/2026, and is only valid as an acknowledgement of the result. To see all the details, review the full monitoring result, which is available on the amfori Sustainability Platform - The English version is the legally binding one.

amfori does not assume any liability with regard to the compliance of this extract, or any versions of this extract, with the Regulation (EU) 2016/679 (General Data Protection Regulation). All rights reserved. No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted, in any form or by any means electronic, mechanical, photocopying, recording or otherwise, be lent, re-sold, hired out or otherwise circulated without the amfori consent. © amfori, 2021